jb Aluminum Electrolytic Capacitor Recommended Conditions

For reflow, use thermal conduction systems such as infrared radiation (IR) or hot blast. Vapor heat 
transfer systems (VPS) are not recommended.

Observe proper soldering conditions (temperature, time, etc.).
Do not exceed the specified limits.
Temperature measuring method: Measure temperature in assuming quantitative production, by sticking the thermo-couple to the capacitor upper part with epoxy adhesives.
Consult us for additional reflow restrictions.

jb Aluminum Electrolytic Capacitor Recommended conditions

For reflow, use thermal conduction systems such as infrared radiation (IR) or hot blast. Vapor heat transfer systems (VPS) are not recommended.

Observe proper soldering conditions (temperature, time, etc.).

Do not exceed the specified limits.

Temperature measuring method: Measure temperature in assuming quantitative production, by sticking the thermo-couple to the capacitor upper part with epoxy adhesives.

Consult us for additional reflow restrictions.

jb Aluminum Electrolytic Capacitor - JNE Features、Construction

jb Aluminum Electrolytic Capacitor - JNE

Features

  • Load life of 2000 hours at 105°C
  • High ripple current
  • Smaller size
  • PCB Mounting

Construction

  • Charge/discharge-proof, polar
  • Aluminum case, fully insulated with PVC
  • Version with PET insulation available
  • Version with additional PET insulation cap on terminal side
  • available for insulating the capacitor from the PCB
  • Snap-in solder pins to hold component in place on PC-board
  • Minus pole marking on case surface
  • Minus pole not insulated from case
  • Overload protection by safety vent on the base